Temperature controller NA8810A+
108.13zł Tax excluded




Temperature controller NA8810A+
Professional temperature controller with NTC sensor included. Features include simple operation and easy installation. The control is based on the on/off (ON-OFF) method with adjustable hysteresis. The regulator has a temperature measurement channel (T1) and a control output (30A). It is used both in refrigeration equipment and installations and in heating processes. It is used in the food industry, plastics processing and everywhere where it is necessary to regulate temperature in a reliable and economical way. We also recommend it to everyone planning to build a backyard smokehouse, for alcohol distillation and other home applications. The controller has dimensions of 78x33mm and is designed to be mounted in a 70x28mm hole in the board, using mounting brackets. The maximum thickness of the board must not exceed 15mm.

Technical data
Name | Description |
Power supply | 230V AC +/-10% |
Adjustable temperature range | -40°C to +149°C |
Resolution of indications and settings | 0,1°C |
Control output | Relay 30A |
Control | ON/OFF with adjustable hysteresis of 0.1-10°C |
Operation mode | Heating or Cooling |
Mounting hole | 70x28mm |
Two-state input | D1 (normally closed or open) |
Temperature sensor | NTC 5KOhm |
Front panel dimensions | 78x33 |
Application:
Thecontroller maintains the set temperature with the set hysteresis through the relay output. Temperature measurement is done through the chamber temperature sensor. The controller can operate in two modes of temperature control: |
HEAT mode

fig. ON-OFF temperature controller - animation heating
Example:
Set temperature (SET): 80,0°C,
Hysteresis (h): 1,0°C
In HEAT mode, the controller starts heating when the temperature of sensor T1 is lower than the set temperature - hysteresis [SET-h], and ends heating when the temperature on the chamber sensor is higher than the set temperature + hysteresis [SET+h].

Fig. ON-OFF temperature controller - drawing heating
COOL mode

fig. ON-OFF temperature controller - animation cooling
Example:
Set temperature (SET): 2,0°C,
Hysteresis (h): 1,0°C
In COOL mode, the controller starts cooling when the temperature of sensor T1 exceeds the set temperature + hysteresis [SET+h], and ends cooling when the temperature at the chamber sensor is lower than the set temperature hysteresis [SET-h].

fig ON-OFF temperature controller - drawing cooling
Movie how to operate NA8810A+ controller
Video how to set up the NA8810A+ controller. What is included in the kit and an example of application.
Connection diagram


Example of application
The controller is used in the food industry (refrigeration chambers), plastics processing and wherever there is a need for reliable and economical temperature control. We also recommend it to everyone planning to build a backyard smokehouse, for alcohol distillation and other domestic applications.

Audible temperature alarm
NA8810A + controller has the function of signaling exceeding the temperature above the set T max value and below T min.
For parameters :
- U52 : Delay for audible temperature alarm.
- U53 : After power supply , delay for the first alarm signal ( 0=function disabled).
- U54 : T max Value that is added to the temperature task causing an audible top alarm if : T read >= T set +U54
- U55 : T min Value that is added to the temperature task causing an audible low alarm if : T read =< T set +U53
Below is an example of use:

D1 input:
When NO or NC contacts No.10 and No.7 are shorted or opened during the operation of the controller, the symbol "iA" will be displayed on the screen, indicating that the controller is locked in response to an external warning signal, which will cause R1 output to open and the buzzer to sound. Manual contacts, e.g. main switch or other external sensors, e.g. inductive, float, limit, optical, audible, etc. can be used to short circuit or open.
Parameters for input D1 (U60):
- 0: (off) NO normally open state (contacts 7 and 10 must be shorted to trigger the alarm).
- 1: NO - when shorted, locked until the "P" key is pressed
- 2: NO - unlocked automatically after opening the contacts normally closed state NC (to trigger the alarm it is necessary to open contacts 7 and 10)
- 3: NC - locked after opening until the "P" key is pressed
- 4: NC - unlocked automatically after shorting the contacts
U61: Delay for external alarm input D1
Dimensions


2 Mounting in a hole of 70 x 28 mm, maximum thickness of the board wall 15mm
3 Mounting brackets included

Set includes

- Temperature controller NA8810A+
- 1x NTC 5kOhm sensor Fi6x30mm cable 2m
- Mounting elements
- User manual in Polish
- Adjustment
- ON/OFF
- Hysteria
- 0,1~10°C
- Control output
- Relays
- Maximum load of the control output
- 30A
- Measurement range
- -40~149°C
- Display
- Digital LCD display
- Mode of operation
- Heating or Cooling
- Display resolution
- 0,1°C
- Obsługa czujników
- (RTD) Resistive NTC 5kOhm
- Panel
- 78x39
- Input
- D1 alarm input
- Assembly
- In a board or hermetic, wall-mounted enclosure
- Mounting hole
- 70x28mm
- Power supply
- 230V AC +/-10%
In Stock
In Stock
18.70zł Tax excluded
There are not enough products in stock
In Stock
In Stock
In Stock
In Stock
In Stock
101.63zł Tax excluded
There are not enough products in stock
In Stock
In Stock
In Stock
In Stock
In Stock
In Stock
In Stock
In Stock
780.49zł Tax excluded
There are not enough products in stock
In Stock
In Stock
In Stock
In Stock
18.70zł Tax excluded
There are not enough products in stock
Precision measurement in industry
10 years of experience
in the industry
14-day right of return
of ordered goods
secure and convenient
online payments
consultant assistance during
ordering
Add a review