Temperature controller RAMP-9
308.94zł Tax excluded
PID temperature controller RAMP 9
Professional industrial electronic PID temperature controller with ramp function. They are used wherever it is necessary to control the rise or fall of temperature over time. It allows you to program temperature control in 16 steps.

pic. Programmable PID temperature controller RAMP-9
Designed for use with injection molding machines, extruders, heating tunnels, heating chambers, soldering stations, packaging machines, welding machines, etc., as well as cooling equipment. Works with temperature sensors and thermocouples - Pt100, J,K,E,S,T,B. Temperature control range up to 1800°C. Series controllers are designed for mounting in control cabinets or switchboards. To mount the regulator in the cabinet, you need to use the mounting elements included in the set.Modern solution of temperature control in these machines - this is the basic parameter of the correct production process.
Technical data
Name | Description |
Power supply | 230V AC |
Control | PID, ON/OFF |
Control accuracy (hysteresis) | 1~1000°C |
Control output | (S) voltage 24V under SSR relay max 30 mA |
Measurement range | 0~1800°C |
Display resolution | 0,1°C |
Display | Display of the set temperature Display of current temperature |
Alarm output | AL1 relay 3A |
Sensor support | (RTD) Resistive Pt100 JPT100 (TC)Thermocouple J,K,E,S,T,B |
Front panel dimensions | 96x96mm |
Program memory | 16 steps |
Degree of protection | IP 65 (front panel) |
Front panel

No. | Symbol | Name | Description |
1 | OUT1 | Display WYJ1 light (red) |
Main control output indicator light |
OUT2 | WYJ2 indicator light (red) |
This product does not have this function. | |
AL1 | Alarm1 indicator light (red) |
The light of the first alarm output. | |
AL2 | Alarm2 indicator light (red) |
Light of the second alarm output. | |
AL3 | Alarm3 indicator light (red) |
This product does not have this function. | |
AT | AT indicator light (green) |
Auto-tuning indicator light | |
2 | SET | SET function key | Menu key / confirmation key to enter or exit the modification or confirm and save the modified parameter. |
3 | < | Shift / AT key | Activation key / Shift key / AT key for automatic tuning (as far as and control mode, long press to enter / exit auto-tuning) |
4 | ^ | Up key |
Up key, in measure and control mode, long press it to switch from RUN / STOP mode or check the menu in reverse order. |
5 | ˇ | Down key |
Down key, check menu in reverse order, long press to enter the program menu. |
6 | SV | Display window Set value (green) |
Set value / parameter display window, control Is stopped when it displays "STOP". |
7 | PV | Display window Current value (red) |
Display window of measured value / parameter code |
Connection diagram

diagram. RAMP-9 connection
Ramp
The ramp function consists in gradual ascent to the newly set setpoint according to the set speed (e.g. 20°C/min). The RAMP-9 controller allows you to set up to 16 ascending ramps (when the value rises to the new value) or descending ramps (when the value falls to the new setpoint).
Programming
The memory of the device allows storing 16 points of the heating curve (heating program). The curve can be divided into subprograms when setting THxx = STOP or RPT which means the end point of the subprogram. If THxx = HOLD is selected, the device when executing the program will automatically enter pause mode (PAUSE) which, unlike STOP/RPT, is not considered the end of the heating program/subprogram.
Example of a program with three subprograms.
The program performs the task of heating to a temperature of SV01=100 degrees during TR01=30 minutes, then maintaining this temperature for a period of TH01=40 minutes, then heating to a temperature of SV02=200 degrees in step 2, cooling to SV03=100 degrees in step 3 and to SV04=25 degrees in step 4 in which the TH04=STOP marker is set.

Fig. Diagram, example of a program with a heating curve.
Operating process and menu

- Adjustment
- PID, ON/OFF
- Hysteria
- 1~1000°C
- Control output
- (S) napięciowe 24V pod przekaźnik SSR max 30 mA
- Maximum load of the control output
- 3A
- Measurement range
- 0~1800°C
- Measurement accuracy
- ±0,5%
- Mode of operation
- Heating or Cooling
- Display resolution
- 0,1°C
- Alarm output
- AL1 relay (3A)
- Obsługa czujników
- (RTD) Resistive PT100, JPT100 / (TC) Thermocouple J,K,E,S,T,B
- Panel
- 96x96mm
- Degree of protection
- IP 65 (panel przedni)
- Power supply
- 230V AC +/-10%
Add a review