Liquid flow sensor designed to read the flow of water or other liquid with a capacity of 15 to 250 L per minute. The sensor sends a corresponding pulse signal. Made of copper body, water impeller and Hall sensor. When water flows through the impeller, it moves the impeller shaft. Its speed changes at different flow rates. The Hall sensor sends a corresponding pulse signal. It can be applied to water heaters, automatic water dispensers mounted on a 1-inch diameter tube or other industrial automation projects.

Technical data
Name | Description |
Power supply | 5-18V DC |
Output | NO signal, OC transistor output(10mA) . >4.7 V DC (input voltage 5 V DC). |
Mounting | 2" male thread |
Power consumption | 15mA (DC 5V) |
Working temperature | 0 - 80 °C |
Range | 15-250 L/min ± 3% |
Volumetric conversion rate | 45 imp/L ± 10% |
Impulse converter | F=0.46*Q-1.1 Q=[L/m] F=[Hz]. |
Tube length | 30 cm |
Material of construction | body: brass turbines: PA66 plastic shaft: stainless steel SUS304 |
Working pressure | ? 1,75 MPa - (17,5 bar) |
Application
- Used to read the rotation of water or liquids
- It can be used in various DIY projects.
Dimensions and wiring diagram

When water flows through the body of the flow meter moves the rotor shaft - the sensor generates the corresponding pulse signal X (specified in the technical data). The number of pulses is proportional to the speed of water flow. Impulses, thanks to meters, can be converted into user-convenient values such as milliliters, liters, liters/min.

Example of application - wiring diagram Pulse counter CA4 + PM flow meter.
This set allows you to measure the volume of liquid. Example: filling tanks with 1.5 l of fluid each tank.

Example of application - connection diagram CI8 pulse counter + PM flow meter.
This set allows both the measurement of the volume of liquid and the number of dosages. Example: filling a series of 10 pieces of tanks with 1.5 l of liquid each tank. When the series of 10 pieces is completed, light notification.


- Assembly
- 2" female thread
- Power consumption
- 15mA (DC 5V)
- Minimum flow for tripping
- 15 L/min
- Maximum flow rate
- 250 L/min
- Operating temperature
- 0 - 80 °C
- Długość przewodów
- 30 cm
- Output
- NO signal, OC transistor output (10mA) min. 4.7 V DC (input voltage 5 V DC)
- Materiał wykonania
- Brass
- Operating pressure
- ≤ 1,75 MPa - (17,5 bar)
- Przelicznik objętościowy
- 45 imp/L ±10%
- Power supply
- 5-18VDC