Fuel or high temperature liquid level sensor PS-B-02-010

Reference:
CZPC-PS-B-02-010

Fuel or high temperature liquid level sensor PS-B-02-010

620.00zł (price includes VAT)

504.07zł Tax excluded

Product details
Hydrostatic liquid level sensor, designed for fuels (ON, beznyna, etc.) and high temperature liquids up to 400°C. Range 0~2m. Made of stainless steel. See details
Materiał wykonania:
Stal nierdzewna SS 316L

Availability: In Stock

Related products
233.00zł

189.43zł Tax excluded

In Stock

Precise regulator - panel meter. Used as an indicator and regulator. Works with sensors having voltage, current or resistance outputs. Dedicated as a liquid level regulator or in other industrial applications.
341.01zł

277.24zł Tax excluded

In Stock

The MG14 meter allows signal conversion to values needed in production, e.g. height, length (mm, cm), pressure, voltage, load. Built-in four relay alarm outputs ALL (b.low), AL (low), AH (high), AHH (b.high).
368.00zł

299.19zł Tax excluded

In Stock

The MG14 meter allows signal conversion to values needed in production, e.g. height, length (mm, cm), pressure, voltage, load. Built-in four relay alarm outputs ALL (b.low), AL (low), AH (high), AHH (b.high).
copy of Measurement kit - length counter copy of Measurement kit - length counter
New

Check out the new product!

299.00zł

243.09zł Tax excluded

In Stock

A kit for measuring the length of a workpiece on a production belt. The kit includes a CI8 pulse counter, a 360 imp/rev incremental encoder, an adjustable arm for the encoder, and a rubber-coated measuring wheel.
Description

Hydrostatic liquid level sensor PS-B-02-010

Submersible water pressure sensor. The pressure exerted by water on the sensor is transmitted as a voltage signal (0 ~ 10 V). The hydrostatic pressure is directly proportional to the immersion. The sensor is designed for use in fuels (diesel, gasoline) as well as in water and high-temperature liquids (up to 400°C). The sensor's capillary is made of SS 316L stainless steel. The signal of the measured liquid pressure is transmitted through a tube to the sensor, which is located in an external, airtight housing. This avoids contact with the measured liquid, which allows use in high-temperature liquids as well as fuels.

Hydrostatyczny czujnik poziomu cieczy PS-B-02-010
pic. submersible, pressure liquid level sensor PS-B-02-010.

Technical data

Name Description
Output signal 0 ~ 10 V
Power supply 12-24V
Measuring range 0 ~ 2m
Working environment temperature 0 ~ +400°C
Protection degree IP68
Construction material SS 316L stainless steel
Capillary length 300cm


Dimensions


rys. Czujnik ciśnieniowy poziomu cieczy PS wymiary i  oznaczenia przewodów.
Fig. PS liquid level pressure sensor dimensions and wire markings.

Application

Dedicated meters for sensors are MG14 meter/regulator with four alarm relays and large display, and SD8V panel meter/regulator with two alarm outputs from Termipol. Thanks to the combination of the measurement result display devices and the sensor, it is possible to continuously control the level with a single sensor. The sensor can be used in water, for example, in a well.

Example of application with pressure sensor and MG14 meter.

Step 1

Set the input signal type Sn = 12 (0~10 V) → see instructions para. 3.

Step 2

Set the minimum display value for the minimum value of the PUL input signal (we will set the display value for 0 V, e.g. 0).

Set the maximum display value for the maximum value of the PUH input signal (we will set the display value for 10 V e.g. 200).


Skalowanie sygnału wejściowego

Fig. Input signal scaling for MG14 meter.

przykład mg14 + ps.png

Fig
. Connection diagram with PS fuel level sensor
animacja_miernik_poziomu_paliwa_mg14.gif

Reading and monitoring of fuel level in the tank using MG14 panel meter and PS-B-02-010 hydrostatic sensor.

Example of application with pressure sensor and SD8V meter.

Step 1

Set the input signal type 1nP = 0_10 (0~10 V) → see instructions para. 1.

Step 2

Set the minimum display value for the minimum input signal value FL = 0 (we will set the display value for 0 V e.g. 0).
Set the maximum display value for the maximum input signal value FH = 3000 (we will set the display value for 10 V e.g. 3000).

Skalowanie sygnału wejściowego dla miernika SD8V
Fig. Input signal scaling for SD8V meter
Data sheet
CZPC-PS-B-02-010
    Measurement range
    Mounting
    No
    Operating temperature
    0 ~ +400 °C
    Degree of protection
    IP68
    Długość przewodów
    300cm
    Materiał wykonania
    Stal nierdzewna SS 316L
    Output signal
    0-10 V
    Measurement medium
    Benzyna, Olej napędowy, woda
    Power supply
    12 - 24 VDC
Shipping
Reviews

Add a review

Add a review

  • Fit:
  • Quality:
  • Trwałość:
  • Użyteczność:
Describe this product using simple and short words.
Drop images here or click to upload.
From the same category
Customers who bought this product also bought
368.00zł

299.19zł Tax excluded

In Stock

The MG14 meter allows signal conversion to values needed in production, e.g. height, length (mm, cm), pressure, voltage, load. Built-in four relay alarm outputs ALL (b.low), AL (low), AH (high), AHH (b.high).
86.00zł

69.92zł Tax excluded

In Stock

Liquid level control relays AFR1 allows to maintain minimum and maximum states. Includes an 8 VAC control voltage source. Designed to work with float sensors.
219.00zł

178.05zł Tax excluded

In Stock

Professional Digital Industrial Timer, indispensable where precise timekeeping is needed in industrial processes. Accuracy of 0.05s. Panel size 72x72mm.
174.00zł

141.46zł Tax excluded

There are not enough products in stock

Float sensor, liquid level, reed switch, 1/2 inch mounting. Made of stainless steel.
333.99zł

271.54zł Tax excluded

In Stock

Designed to work with proximity sensors, incremental encoders. It has a prescaler function and two relay outputs.
341.01zł

277.24zł Tax excluded

In Stock

The MG14 meter allows signal conversion to values needed in production, e.g. height, length (mm, cm), pressure, voltage, load. Built-in four relay alarm outputs ALL (b.low), AL (low), AH (high), AHH (b.high).

Menu

Homepage

Menu