
Liquid level sensor PS-C-02-420-D designed for operation in acids
819.51zł Tax excluded
Hydrostatic liquid level sensor PS-C-02-420-D
Submersible liquid pressure sensor. The pressure exerted by the liquid on the sensor is transmitted as a voltage signal (4-20 mA). The hydrostatic pressure is directly proportional to the submersion. The sensor is designed for operation in acids (hydrochloric acid, sulfuric acid, hydrofluoric acid, sodium hydroxide, hydrogen peroxide and other highly corrosive liquids, chemical and galvanic wastewater). The sensor capillary is made of F4 tetrafluoro. The signal of the measured pressure of the liquid is transmitted through a tube to the sensor, which is located in an external, hermetic housing.

Technical data
Name | Description |
Output signal | 4-20 mA |
Power supply | 12-24V |
Measuring range | 0 ~ 2m |
Working environment temperature | -40 ~ +150°C |
Degree of protection | IP68 |
Construction material | F4 tetrafluoro |
Capillary length | 300cm |
Dimensions

Application
Dedicated meters for the sensors are the MG14 meter/regulator with four alarm relays and a large display, and the SD8V panel meter/regulator with two alarm outputs from Termipol. By combining the measurement result display devices and the sensor, it is possible to continuously control the level with a single sensor. The sensor can be used in tanks for fuel, oil or high temperature liquids.
Example of application with pressure sensor and MG14 meter.
Step 1
Set the input signal type Sn = 22 (4-20mA) → see instructions para. 3.
Step 2
Set the minimum display value for the minimum value of the PUL input signal (we will set the display value for 0 mA, e.g. 0).
Set the maximum display value for the maximum value of the PUH input signal (we will set the display value for 20 mA e.g. 200).


Example of application with pressure sensor and SD8V meter.
Step 1
Set the input signal type 1nP = 4_20 (4-20 mA) → see instructions para. 1.
Step 2
Set the minimum display value for the minimum value of the input signal FL = 0 (we will set the display value for 0 mA, e.g. 0).
Set the maximum display value for the maximum input signal value FH = 3000 (we will set the display value for 20 mA e.g. 3000).


Fig. Connection diagram with fuel level sensor PS
- Measurement range
- Mounting
- No
- Operating temperature
- 0 ~ +400 °C
- Degree of protection
- IP68
- Długość przewodów
- 300cm
- Materiał wykonania
- Stal nierdzewna SS 316L
- Output signal
- 0-10 V
- Measurement medium
- Benzyna, Olej napędowy, woda
- Power supply
- 12 - 24 VDC
Add a review
Add a review