Flow Meter PM1/4

External 1/4 inch thread assembly. Range: 0.35-3 L/min ± 3%.

  • Add feedback:
  • Code: PM-1/4-B
  • Availability: Exists Exists

  • Net Price: 62.60 zł 77.00 zł
  • pcs.
  • Payment on delivery, Traditional Bank Transfer (Pro forma), Fast online payments

The product is shipped within 24 hours.

We complete the order within 24 hours.

The product is covered by a one-year warranty.

You can return the product within 14 days.

Technical Data

Power supply: 5-18 VDC
Output: NO, wyjście tranzystorowe OC (10mA) min. 4,7 VDC (napięcie wejściowe 5 VDC)
Material of execution: Brass
Assembly: External thread 1/4'' Inch
Minimum flow: 0,35 L/min
Max. Flow: 3 L/min
Wire lengh: 30 cm
Work pressure: ≤ 1,75 MPa - (17,5 bar)
Working Conditions: 0 ~ 80°C
Volume Converter: 4380 imp/L ± 10%

Flow Sensor PM-1/4-B

The flow sensor is designed to read the flow of water or other liquid with a flow rate of 0.35 to 3 L per minute. High sensitivity allows for the detection of even small liquid flows. The sensor sends a corresponding pulse signal. It has a body made of brass, a water impeller and a Hall sensor. When water flows through the impeller, it moves the impeller shaft. Its speed changes at different flow rates. The Hall sensor sends a corresponding pulse signal. It can be applied to water heaters, automatic water dispensers mounted on 1/4-inch diameter pipe or other industrial automation projects.Flowmeter PM-1/4-B

Fig. Flow Sensor PM-1/4-B

 

Application

  • Used to read the rotation of water or liquids
  • Can be used in various DIY projects.

 

Dimensions and wiring diagram

Flowmeter PM-1/4-B - Dimensions
Fig. Flowmeter PM-1/4-B - Dimensions.


When water flows through the flowmeter body, the impeller shaft is moved - the sensor generates the corresponding X pulse signal (specified in the technical data). The number of pulses is proportional to the water flow rate. The pulses can be converted to user-friendly values such as milliliters, liters, liters/min using meters.

 

pm operating principle
Fig. Flowmeter operating principle.

Example of application - connection diagram Pulse counter CA4 + flowmeter PM

This set allows for the measurement of liquid volume. Example: filling tanks with 1.5 l of liquid each tank.

Connection diagram of CA4 Pulse Counter + PM flowmeter
Fig. Connection diagram of CA4 Pulse Counter + PM flowmeter.


Example of application - connection diagram of CI8 Pulse Counter + flowmeter PM

This set allows for both the measurement of fluid volume and the number of doses. Example: filling 10 tanks with 1.5 l of fluid each tank. After completing the series of 10 pcs. light notification.

Connection diagram of CI8 Pulse Counter + flowmeter CP
Figure. Schematic connection of CI8 Pulse Counter + Flow Meter PM.


Dosing, filling tanks.
Animation. Dosing, filling tanks.

Types of Hydraulic Threads

Types of Hydraulic Threads

Hydraulic Threads Converter Below we present a table of types of threads for flow sensors, flowmeters and temperature and pressure sensors that can be found in our store. More