Technical Data

Power supply: 24 VDC
Output: 0-10 V
Range: 0 ~ 10m
Accuracy of measurement: +/- 0,5%
Sensor wire: Rubber
Material of execution: Stainless Steel
Mounting: Brak
Measurement: Water
Degree of Protection: IP 68
Wire lengh: 11 m
Working Conditions: -10 ~ 85 °C

Hydrostatic Liquid Level Sensor PS-10-010

Submersible pressure water sensor. The pressure exerted by the water on the sensor is transmitted in the form of a voltage signal (0 ~ 10 V). Hydrostatic pressure is directly proportional to immersion. The sensor is designed for use in water. The pressure level sensor is usually mounted in a vertical position (e.g. in a well), hanging on a cable. If the sensor may be exposed to movement during measurement, the sensor position must be secured to prevent errors. This can be done with a tube or weight placed on the probe.

Resistive Liquid Level Sensor HT-R-250
Fig. Submersible, pressure liquid level sensor PS-10-010.


Dimensions

 

Figure. Pressure sensor of liquid level PS dimensions and wire markings.
Figure. Pressure sensor of liquid level PS dimensions and wire markings.

Application

Dedicated meters for sensors are: meter/regulator MG14 with four alarm relays and a large display and panel meter/regulator SD8V with two alarm outputs from Termipol. Thanks to the connection of the display devices and the sensor, continuous level control is possible using one sensor. The sensor can be used in water, e.g. in a well.

Example of application with a pressure sensor.

Step 1

Set the input signal type Sn = 12 (0~10 V) → see instruction point 3.

Step 3

Set the minimum display value for the minimum input signal value PUL (we will set the display value for 0 V e.g. 0).

Set the maximum display value for the maximum input signal value PUH (we will set the display value for 10 V e.g. 500).

 

Scaling of the input signal

 

Fig. Scaling of the input signal Volt

 

Example MG14 + PS.png

 

Fig. Connection diagram with water level sensor PS

Reading and monitoring of water level in the tank using the MG14 Panel Meter and PS series hydrostatic sensor.